Suggest the following:
1. Establish the conditions the PWA will experience in the 'end use
environment'.
2. Try to mimic it as closely as possible in a well-accepted SIR regimen. For
no clean, try the John Sohn SIR conditions so the residues don't evaporate
and confound the results. [Doug Pauls, please add these to the discussion.]
3. Test PWAs prepared and soldered under the same conditions as the SIR
boards for residual ionics.
4. When you find SIR results that meet your end use environment, matching
ionics level will serve as a reasonable process monitoring level.

Bill Kenyon
Global Centre Consulting
3336 Birmingham Drive
Fort Collins, CO   80526
Tel: 970.207.9586   New Cell: 970.980.6373

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2