Greetings everyone,
I have two customers, both of whom use pulse plating to fabricate boards.
One has a continuous copper deposit and the other has multiple bands or layers
of plating - very visible after microetch.

The plating deposit on the banded product has cracks after Thermal Stress.

In my limited experience I have not seen pulse plating result in such
definite bands.

My question is  - would bands be expected and "normal" in some pulse plating
operations?

Thanks for your help

Susan Mansilla
Robisan Lab

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2