I would look at making sure the materials contacting the external cap
layers are not influencing the movement of the rigid material during
lamination.  For example a duofoil sheet tends to hold the oxide finish
of that cores foil and prevent the core from moving as predicted - this
may cause unique issues around the panel that could show the issues that
you are describing.  This coupled with the relieved areas of rigid that
are part of the package can produce some odd registration issues.  I
this makes sense to the condition that you are seeing, I will suggest
developing a clutch system between the separator materials and the oxide
foils of the core to allow for freedom of movement when the stress is
released above the c-stage Tg.  B-stage can be used to provide the
clutch effect needed.


Jeffrey Bush
Director, Quality Assurance and Technical Support

                          76 Technology Drive - POB 1890
                             Brattleboro, Vermont 05302-1890
                                Tel. 802.257.4571.21 Fax. 802.257.0011
                                    [log in to unmask]
                              http://www.vtcircuits.com	



-----Original Message-----
From: Tuan Le [mailto:[log in to unmask]] 
Sent: Thursday, October 07, 2004 6:07 PM
To: [log in to unmask]
Subject: Re: [TN] Registration problem


These panels have cap lam construction and rigid layers are outside
layers, all flex are inside.

Tuan

-----Original Message-----
From: Jeffrey Bush [mailto:[log in to unmask]] 
Sent: Thursday, October 07, 2004 12:07 PM
To: [log in to unmask]
Subject: Re: [TN] Registration problem

What/where are the rigid layers in the stack?



Jeffrey Bush
Director, Quality Assurance and Technical Support

                          76 Technology Drive - POB 1890
                             Brattleboro, Vermont 05302-1890
                                Tel. 802.257.4571.21 Fax. 802.257.0011
                                    [log in to unmask]
                              http://www.vtcircuits.com	



-----Original Message-----
From: Tuan Le [mailto:[log in to unmask]] 
Sent: Thursday, October 07, 2004 2:47 PM
To: [log in to unmask]
Subject: Re: [TN] Registration problem


The panel sizes vary from 12x18 to 18x24, 12 to 16 layer board having 4
to 5 flex cores (0.002" 1oz/1oz or 0.002" 2oz/2oz), panel thickness is
from 0.090" to 0.133".  The layers are laminated using 4-slot toolings.

Tuan Le

-----Original Message-----
From: Jeffrey Bush [mailto:[log in to unmask]] 
Sent: Thursday, October 07, 2004 10:12 AM
To: [log in to unmask]
Subject: Re: [TN] Registration problem

What is the contruction of the package and how is it laminated.



Jeffrey Bush
Director, Quality Assurance and Technical Support

                          76 Technology Drive - POB 1890
                             Brattleboro, Vermont 05302-1890
                                Tel. 802.257.4571.21 Fax. 802.257.0011
                                    [log in to unmask]
                              http://www.vtcircuits.com	



-----Original Message-----
From: Tuan Le [mailto:[log in to unmask]] 
Sent: Thursday, October 07, 2004 1:53 PM
To: [log in to unmask]
Subject: [TN] Registration problem


Hello Technetters,
 
Lately I have been having this problem with some rigid-flex panels:
 
X-ray after drill shows good registration on coupons (which are located
at each corner and along the edges) but bad registration inside the
panels (from small annular rings to breakouts).  
* Everything on a layer is scaled from the center of the layer.  
* Layer to layer registration is good.  Inside the panel, however,
registration is good on the lower left corner but starts getting bad
towards the right and top of the panel making it look like drill is
scaled from the lower left corner.  Drill operator confirms that drill
is scaled from the center not the corner.
 
I can't explain how this problem happened and would appreciate any help.
 
Thank you in advance.
 
Tuan Le
 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2