September 12, 2004

We think root cause is poor PTH copper plating process control which allowed excessive build up of the copper.  Subsequent abrasion of the tin/lead plating over the copper with scotch brite allowed slivers of tin/lead/copper to flake off and become randomly dispersed over the surface of the PWB.  The ionic contamination test done just prior to solder mask did not detesct these slivers, and I would not expect it to..  Unfortunately the pre-solder mask coating did not remove these.  Attached is picture of one of the MIL-P-55110 test coupons which shows excessive copper plating bulidup.
  ----- Original Message ----- 
  From: Susan Mansilla<mailto:[log in to unmask]> 
  To: [log in to unmask]<mailto:[log in to unmask]> 
  Sent: Friday, September 10, 2004 9:01 PM
  Subject: Re: [TN] PWB Conductive Contamination Under Solder Mask; What Can Cause ...


  Since Jeff volunteered me, I would be happy to take a look and post photos so
  we can all see this phenomena that has all of us puzzling.

  Susan Mansilla
  Robisan Lab

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 1.8e
  To unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask]> with following text in
  the BODY (NOT the subject field): SIGNOFF Technet
  To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or (MAIL)
  To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest
  Search the archives of previous posts at: http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>
  Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16> for additional information, or contact Keach Sasamori at [log in to unmask]<mailto:[log in to unmask]> or 847-509-9700 ext.5315
  -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2