Hello together!
Graham,
I have a little confunsion with the units of the ionic contamination... are
they "mg/cm2" or "microgram/cm2"?
It would be a good thing to be able in Outlook to include greek letters!
Best regards
--
José Antonio García Ontalba
Quality department
NAGARES, S.A.
Ctra. Madrid-Valencia, Km. 196
16200 Motilla del Palancar (Spain)
Tel: 00 34 969 18 00 21
Fax: 00 34 969 33 11 31
E-mail: [log in to unmask]
--
-----Mensaje original-----
De: TechNet [mailto:[log in to unmask]]En nombre de Douglas O. Pauls
Enviado el: martes, 31 de agosto de 2004 22:21
Para: [log in to unmask]
Asunto: Re: [TN] Ionic contamination of PCA
Graham,
The hanging one is a piece of "rope", which, by the way is 8.4 meters long.
String is entirely different.
I would be curious as to the studies which set the 0.2 microgram / cm2
level. Use of a more modern dart board, no doubt.
Doug Pauls
Graham Naisbitt
<Graham.Naisbitt@con To: IPC TechNet
<[log in to unmask]>, Doug Pauls <[log in to unmask]>
coat.co.uk> cc:
Subject: Re: [TN] Ionic
contamination of PCA
08/31/2004 08:48 AM
Doug
If that is the piece of string you were keeping to hang someone with, its
too short!
Irving,
Most of our customers presently employ a go/no-go at something less than
0.2microgrammes of NaCl equivalence per cm2. The old 1.5 limit may be too
high for many modern circuit designs. Remember, that old spec should be
interpreted as: It is acceptable to leave UP TO 1.5mg/cm2 on your assembly
surface, and that cant be a good thing.
--
Regards Graham Naisbitt
[log in to unmask]
Concoat Limited - Engineering Reliability in Electronics
A British Manufacturer
www.conformalcoating.com www.concoat.co.uk www.concoatsystems.com
Golf Quote of the week: I may be the only golfer never to have broken a
single putter...if you don¹t count the one I twisted into a loop and threw
into a bush.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------
__________ Información emitida por NOD32 __________
Este mensaje ha sido verificado por NOD32 antivirus system.
http://www.nod32.com
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|