How about letting them run on a deviation?
Dave C.

-----Original Message-----
From: Bloomquist, Ken [mailto:[log in to unmask]]
Sent: Monday, August 02, 2004 11:37 AM
To: [log in to unmask]
Subject: [TN] Lead Finish


I have a question on defining a lead finish on magnetics made by CM's.

On our magnetics design drawings we currently call out SN63 for a lead
finish but we have a contractor that wants to us SN60. We don't have a
problem using SN60 but we'll have to change all our drawings to accept it.
When we change to Lead Free solder in the future we'll have to change all
our drawings again.

I'm wondering if there is a better way to call out a lead finish i.e. "Lead
finish shall be solderable" or something simple like that. Or maybe there is
a spec I can call out.

What do others of you do for specifying lead finish on internally designed
components that are manufactured by a CM?

Thanks to all,

KennyB

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2