        Hi Kenny:
        Agree, you should give yourself some wiggle room. An alternate part list drawing will also work. This drawing will affect all drawing. So every time you want to add a part to the drawings all you have to do is add it to the alternate part list. The drawing should have a table of components with two or more columns. On the left the alternate part and on the right of it the parts it is replacing.
        Regards,
        Ramon

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Clyde Sprowl
Sent: Monday, August 02, 2004 12:53 PM
To: [log in to unmask]
Subject: Re: [TN] Lead Finish


Your note should say "Leads shall be solder coated using SN63 or (your
company name) Engineering approved equivalent. Contract Manufacturer
shall secure written deviation from this requirement in advance."

This will allow you to change requirements without changing your
drawings every time, and still provide a paper trail. Also, if your
company is like most, the order of procurement authority has the
Purchase Order the supreme authority. You Purchasing department should
be able to amment the requirements by issuing a PO suppliment.

Sincerely,
Clyde

>>> [log in to unmask] 08/02/04 11:36AM >>>
I have a question on defining a lead finish on magnetics made by CM's.

On our magnetics design drawings we currently call out SN63 for a lead
finish but we have a contractor that wants to us SN60. We don't have a
problem using SN60 but we'll have to change all our drawings to accept
it. When we change to Lead Free solder in the future we'll have to
change all our drawings again.

I'm wondering if there is a better way to call out a lead finish i.e.
"Lead finish shall be solderable" or something simple like that. Or
maybe there is a spec I can call out.

What do others of you do for specifying lead finish on internally
designed components that are manufactured by a CM?

Thanks to all,

KennyB

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2