We just returned from a seminar by Cookson which said 1% would be
contamination point. Additional solder bars without copper would need to be
added to bring the balance in line. I imagine now we would need to have SAC
bars and SA bars to keep balance, either way close monitoring of pot
composition seems to be inevitable.
Dave C.
-----Original Message-----
From: Richard Kraszewski [mailto:[log in to unmask]]
Sent: Wednesday, August 18, 2004 4:08 PM
To: [log in to unmask]
Subject: [TN] Allowable copper contamination for SAC 305?
If one was to use a SAC305 alloy in a wave or selective soldering
application, how much copper contamination do you think would be
allowable before the melting range would become unacceptable. From what
I can see from the phase diagram, it appear one might be OK until you
reached ~ 0.8-0.9% copper?
Your thoughts would be appreciated.
Rich K / KEDS
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|