TECHNET Archives

July 2004

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Leo Higgins <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Thu, 1 Jul 2004 23:17:57 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (76 lines)
Is this soak at heat up of cool down?  For heat up the flux functionality is
likely to be destroyed.  If the flux is not destroyed, one possible
benefit(?) is the likely reduction of voids in the solder balls, but even
this is not clear because some evidence shows improved SMT T/C results if
fine voids are present near the solder ball to substrate interface.  But
this benefit(?) can be realized with much less reduction in effective heat
up rate.  Five to 10 minutes is very extreme.

For cool down you are likely to significantly coarsen the solder
microstructure which is likely to reduce surface mount temp cycle
reliability performance.

This soaking is not a good idea.

Regards,
Leo

------------------------------------
Leo M. Higgins III, Ph.D.
Director of Applications Engineering / ASAT Inc.
[log in to unmask]
3755 Capital of Texas Hwy-So
Suite 100
Austin, TX     USA     78726
tel: 512-383-4593
fax: 512-383-1590
mobile: 512-423-2002
------------------------------------


-----Original Message-----
From: Rick Thompson [mailto:[log in to unmask]]
Sent: Thursday, July 01, 2004 10:54 PM
To: [log in to unmask]
Subject: [TN] Long Reflow Soak Times for BGAs?


I'm having a philisophical discussion with my boss regarding long reflow
soak times to improve soldering under BGA devices.  Is there anything to be
gained by extending soak times at the 150C level from 60-90 seconds to 5-10
minutes? I've never seen times this extended and am wondering if they make
sense in some situations?  The boards in question are not terribly
difficult, .063" thick, 14 layer, 12x16 inches with maybe a couple thousand
components on top.  Any comments on this practice?

Thanks in advance,

Rick Thompson

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

This e-mail and any files transmitted with it are confidential and
intended solely for the use of the individual or entity to whom
they are addressed.
If you have received this e-mail in error please notify the
originator of the message. This footer also confirms that this
e-mail message has been scanned for the presence of computer viruses.

Any views expressed in this message are those of the individual
sender, except where the sender specifies and with authority,
states them to be the views of SMTEK International Inc.

Scanning of this message and addition of this footer is performed
by SurfControl E-mail Filter software in conjunction with
CA e-trust anti-virus detection software.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2