7628 glass has different yield thickness based on resin content and the
rheology.  You can purchase 7628 in epoxy from a yield per ply thickness
of .0065" to where you are with yours.  7629 glass can give you up to
.009" in yield as this is some what heavier glass.  I think the standard
has been a .007" per ply yield - this is fairly standard from laminate
suppliers.



Jeffrey Bush
Director, Quality Assurance and Technical Support

                          76 Technology Drive - POB 1890
                             Brattleboro, Vermont 05302-1890
                                Tel. 802.257.4571.21 Fax. 802.257.0011
                                    [log in to unmask]
                              http://www.vtcircuits.com	



-----Original Message-----
From: Andrew Medina [mailto:[log in to unmask]] 
Sent: Monday, July 12, 2004 11:35 PM
To: [log in to unmask]
Subject: Re: [TN] 7628 prepreg?
Importance: High


Since were discussing about the 7628 prepreg,. Does anybody know the
standard thickness of this prepreg type.

In our process we are getting around 0.22 mm,


Andrew J. Medina
Quality Control Section
QM Department
Daeduck Phils.,  Inc.
Tel # : 046-4370747 loc 293
Fax # : 046-437-0749
Mobile # : +639275312569
E-mail : [log in to unmask]



Jeffrey Bush <[log in to unmask]>
Sent by: TechNet <[log in to unmask]>
07/12/2004 08:40 PM
Please respond to
"TechNet E-Mail Forum." <[log in to unmask]>; Please respond to Jeffrey
Bush <[log in to unmask]>


To
[log in to unmask]
cc

Subject
Re: [TN] 7628 prepreg?






Common type, stable, low resin content and likely predicable thickness
is this is important.  Otherwise PCB house should be left to determine
the optimal stack for the board geometry and end use.



Jeffrey Bush
Director, Quality Assurance and Technical Support

                          76 Technology Drive - POB 1890
                             Brattleboro, Vermont 05302-1890
                                Tel. 802.257.4571.21 Fax. 802.257.0011
                                    [log in to unmask]
                              http://www.vtcircuits.com



-----Original Message-----
From: Brooks,Bill [mailto:[log in to unmask]]
Sent: Friday, July 09, 2004 5:08 PM
To: [log in to unmask]
Subject: [TN] 7628 prepreg?


Bill Brooks
PCB Design Engineer , C.I.D., C.I.I.
Tel: (760)597-1500 Ext 3772 Fax: (760)597-1510 http://pcbwizards.com

Why would a designer specify 7628 prepreg in the construction of a
board? What characteristics are unique to it? Bill Brooks, CID

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-509-9700 ext.5315
-----------------------------------------------------


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2