TECHNET Archives

July 2004

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum.
Date:
Fri, 23 Jul 2004 15:38:48 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (127 lines)
Yes, I have heard of this, but with respect to x-ray inspection, not optical.  On the x-ray its easy to see if the extension of the pad has been wetted by the ball.  Its not as easy to see if a ball/pad has flowed if the ball is completely in line with the pad.  The 'extension' whether it be a teardrop, or just a trace stub, needs to be unmasked.  I suspect that optical and x-ray inspection has improved to the extent that this technique probably isn't as useful as it once may have been.

Gary Crowell
Micron Technology


> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]]On Behalf Of Dave Seymour
> Sent: Friday, July 23, 2004 2:55 PM
> To: [log in to unmask]
> Subject: Re: [TN] BGA Land Patterns
> 
> 
> This request is not for Soldermask defined pads.
> 
> The Request is for diamond or a tear drop shaped
> copper land patterns for the BGA pins. Just curious if
> anyone out there had seen this.
> 
> Thanks,
> dave
> 
> 
> Werner Engelmaier wrote:
> 
> >Hi Tom,
> >The problem with SMD-SJs [solder-mask-defined] is that the 
> SJ geometry
> >results in a stress concentration where it is shaped by the 
> solder mask--it has
> >nothing to do with bonding area or overall strain distribution.
> >
> >Regards,
> >Werner Engelmaier
> >Engelmaier Associates, L.C.
> >Electronic Packaging, Interconnection and Reliability Consulting
> >7 Jasmine Run
> >Ormond Beach, FL 32174 USA
> >Phone: 386-437-8747, Fax: 386-437-8737, Cell: 386-316-5904
> >E-mail: [log in to unmask], Website: www.engelmaier.com
> >
> >
> >
> 
> David Seymour wrote:
> 
> >To All,
> >
> >
> >
> >I just had an assy house recommend a diamond shape
> >
> >or tear drop shape for a BGA land pattern to allow for better
> >
> >optical inspection related to reflow and solder opens detection.
> >
> >
> >
> >Has anyone come across a white paper or reliability study
> >
> >for or against alternative pad shapes for BGAs?
> >
> >
> >
> >dave
> >
> >---------------------------------------------------
> >Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> >To unsubscribe, send a message to [log in to unmask] with 
> following text in
> >the BODY (NOT the subject field): SIGNOFF Technet
> >To temporarily halt or (re-start) delivery of Technet send 
> e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> >To receive ONE mailing per day of all the posts: send e-mail 
> to [log in to unmask]: SET Technet Digest
> >Search the archives of previous posts at: 
> http://listserv.ipc.org/archives
> >Please visit IPC web site 
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 
> additional information, or contact Keach Sasamori at 
> [log in to unmask] or 847-509-9700 ext.5315
> >-----------------------------------------------------
> >
> >
> >
> >
> 
> --
> Dave Seymour, CID+
> Catapult Communications Inc.
> 800 Perimeter Park Dr, Suite A
> Morrisville, NC 27560
> 
> Direct: (919)653-4249
> Main: (919)653-4180
> Fax: (919)653-4297
> 
> [log in to unmask]
> 
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with 
> following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send 
> e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail 
> to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: 
> http://listserv.ipc.org/archives
> Please visit IPC web site 
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 
> additional information, or contact Keach Sasamori at 
> [log in to unmask] or 847-509-9700 ext.5315
> -----------------------------------------------------
> 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2