Jim,
I have seen this in the past.  On some proto boards that we really needed,
so tried a few different things to convince ourselves that they were
acceptable.

I believe that our vendor did not do a good micro etch before HASL, much
like you and your vendor are thinking.  Unfortunately in my case, my vendor
was convinced it was an intermetallic problem caused by baking during cure
of the silkscreen legend ink.  We didn't really buy into that idea.

We wound up having another house make the boards instead, since he kept
insisting there was nothing wrong, and he just needed to run a few more
profiles on his legend curing oven...

In your case I would imagine that you could strip the solder, be sure you do
a good job prepping the pads and re HASL.

Good Luck,
Hal

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Marsico, James
Sent: Tuesday, July 20, 2004 3:29 PM
To: [log in to unmask]
Subject: [TN] PWB SOLDERABILITY


Good Day Technet:

Here's an unusual situation.  We recently got a lot of PWBs from our
supplier who we've been using for years.  The solder on the boards (HASL)
looks good, thick and shiny.  A couple of weeks ago, after SMT assembly with
a fairly aggressive water soluble solder paste, we noticed that one of the
components (diode) had fallen off and was sitting on the operator's bench.
The pads on the board where the component had fallen off showed bare copper,
while the solder fillets remained on the component!  Thinking that this was
an unexplainable one-time occurrence, the component was soldered back on and
the board went on its merry way.  Well,  a couple of days later, boards from
the same lot were soldered and we noticed that some of unused pads or test
pads were copper only, with no traces of solder.  We then took some bare
boards, all of which looked good, and ran them trough our reflow and in-line
cleaning process (no flux or solder paste).   Low and behold, on about 20%
of the boards there were copper pads with no solder, and a few pads where
the solder was partially peeling off the pads, exposing the copper
underneath (with no traces of copper on the pealed solder).  After
discussions with our supplier, we both came to the conclusion that some of
the boards must have been oxidized to such a degree that solder coated the
pads but did not achieve a metallurgical bond.  I would have thought that
such a condition would result in a de-wet or non-wet condition, but, as I
said earlier, the boards looked great!

Has anyone else ever come across this before?

Jim Marsico
Senior Engineer
Production Engineering
EDO Electronics Systems Group
[log in to unmask] <mailto:[log in to unmask]>
631-595-5879

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2