For a start, check out IPC-2222, Table 9-3, for Plated-Through Hole Diameter to Lead Diameter Relationships. If auto-insertion is used, what is recommended by the inserter mfgr? If press-fit or other specialty part, what is the mfgr's recommendations? Also take into account hole size tolerance and true position tolerance; The table mentioned above (IMHO) is suitable for most applications.
Have a good day:)
Roger Stoops
-----Original Message-----
From: Pasquito, Helena [mailto:[log in to unmask]]
Sent: Monday, July 12, 2004 12:39 PM
Subject: Pin Size vs. Plated Through Hole Size
I am looking for a specification that would have information on 'pin size'
vs. 'plated through hole size' design requirements/recommendations/limits
for wave soldering applications. Does anyone know of any such specification
(internal or external)?
Thank you for any help you can offer.
Helena Pasquito
Quality Training Admin./CRM
Tyco Electronics M/A-COM
1011 Pawtucket Blvd. M/S150
Lowell, MA 01853
Phone 978-442-5024
Email [log in to unmask]
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|