Joe

At present there is no formal SIR spec you can use.

I have a draft of the new specs that I can send you if you you wish. This is
being used by several companies now to characterise their manufacturing
process.

Please contact me directly off-line if you want a copy.

If Steve is watching, maybe you put a pdf onto your web site?
--
Regards Graham Naisbitt

Golf Quote of the week: I was 3 over: one over a house, one over a patio and
one over a swimming pool!

[log in to unmask]

Cell: 079 6858 2121
Office: +44 (0)1252 813706

Concoat Limited - Engineering Reliability in Electronics

NEW Additional Web address: www.conformalcoating.com

www.concoat.co.uk     www.concoatsystems.com


> Fellow technets,
>
> We are in the process of selecting a new saponifier for our in-line cleaner
> and developing the accept/reject criteria for the selection.  We mainly use
> RMA fluxes on densely populated, double sided smt boards with various BGAs.
> The typical visual and ionic contamination tests (using an Omegameter) will
> be run using test boards, and we would consider other tests as required such
> as having a lab perform a SIR test.  Some suppliers of saponifiers have
> offered to run cleanliness test as part of the evaluation process.
>
> Would anyone like to comment on:
> *       What types of tests should be run to determine the cleanliness of a
> populated board when evaluating different saponifiers?
> *       What IPC spec defines the SIR requirements and methodology?  What
> are the benefits of running a SIR type of test as far as cleanliness goes?
>
> Look forward to your inputs.  thanks again
>
> joe
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
> additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2