Jeff and Roger - You've both proposed these vias be filled with conductive
via fill.  But the fill does not need to be conductive.  We've used both
types of fill materials and found the non-conductive to have superior
processing capability.

Mike McMaster
RF Product Engineer
Merix Corporation
503-992-4263



> ----------
> From:         Jeffrey Bush[SMTP:[log in to unmask]]
> Reply To:     TechNet E-Mail Forum.;Jeffrey Bush
> Sent:         Friday, June 25, 2004 9:20 AM
> To:   [log in to unmask]
> Subject:      Re: [TN] VIA in Pad
>
> I will suggest a conductive via fill in these areas to provide a flat
> SMT site, because - solder joint could be starved by flow down into the
> via.  Also Sm plugged on the opposite side will also cause excessive
> voiding as the capped via will provide a good outgassing effect during
> relow.  Not the cheapest solution but is effective in hiding vias in
> pad.
>
>
>
> Jeffrey Bush
> Director, Quality Assurance and Technical Support
>
>                           76 Technology Drive - POB 1890
>                              Brattleboro, Vermont 05302-1890
>                                 Tel. 802.257.4571.21 Fax. 802.257.0011
>                                     [log in to unmask]
>                               http://www.vtcircuits.com
>
>
>
> -----Original Message-----
> From: Tom Parkinson [mailto:[log in to unmask]]
> Sent: Friday, June 25, 2004 11:14 AM
> To: [log in to unmask]
> Subject: [TN] VIA in Pad
>
>
> We're a CM.  One of our customers is asking us to build a board assembly
> that will be using BGAs with VIAs in pads.  They are in the design
> stages at this point, and we have some concerns with having a Via in the
> middle of a BGA pad.  Anyone have suggestions and/or experience with
> this??
>
> Thanks
>
>
> Tom Parkinson - Quality System Manager - CIT
> WinTronics, Inc.
> Ph: 724-981-5770 Ext. 235
> Fax: 724-981-1772
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
> unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
> (re-start) delivery of Technet send e-mail to [log in to unmask]: SET
> Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
> posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
> archives of previous posts at: http://listserv.ipc.org/archives Please
> visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
> additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2