Mornin' Joe!

I just switched from Kyzen XJN to 4512P. We got a new batch cleaner (Aqueous
Technologies SMT800) that replaced the Electrovert MCS-1000 that we had.

The MCS had some pretty powerful pumps which provided quite a bit of
impingment forces which the XJN needed to clean well. The 4512P provides for more
solvency which doesn't require the high horsepower pumps to clean well. We clean
Indium SMQ92J no-clean residues and it does a good job.

As for the Armakleen, I was told they were using it for a time here before I
started in the MCS-1000, and it left this sodium bicarbonate like residue all
over the machine. There was still some inside the machine even today. I was
told that because of the residue, the pump seals were destroyed and had to be
replaced. That's when they switched to the Kyzen XJN here...don't know if the
Armakleen E-2003 still does the same thing.

-Steve Gregory-


> Fellow Technets,
>
> We are evaluating a couple of different saponifiers to remove RMA flux
> residue using a WESTEK in-line cleaner.  The 2 saponifiers are as follows:
>         - Kyzen,  Aquanox A4512P
>         - AlphaMetals,  Armakleen E-2003
>
> Both appear to be capable based on manufacturer's literature.  Would anyone
> like to share their experience with either of these products and state which
> type of flux type are cleaning?  It is always very helpful to hear from
> actual users.  thanks
>
> joe
>


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2