Hi Phil,
There is no impact of 105 sec instead of 90 sec above Liqidus. Remember that,
for the reflow soldering time above Liquidus is a meaningless number. For
Sn63Pb37 solder, time above Liquidus+20°C when soldering to copper [that does not
mean soldering to already solder-wetted copper], and Liquidus+35°C when
soldering to nickel/Alloy42 is the important parameter, and needs to be 5 sec or
longer for the slowest heating connection.
Regards,
Werner Engelmaier
Engelmaier Associates, L.C.