Hi again,

I forgot to ask if you were cleaning your boards ?  Is so what is your
process and media ?

Leigh Jansen (Mr)

Technical Support Manager

Concoat Limited - Engineering Electronics Reliability

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Lance Mayes
Sent: 10 June 2004 00:18
To: [log in to unmask]
Subject: [TN] Conformal Coating
Importance: High

Hello again Techies;

We are having issues with our conformal coating on some of our
components.
 It pulls back from some of the components leads along the edges.
We are wondering if this will make a difference in the protection of the
board.
We're using Humiseal Acrylic 1B31 and Humiseal Thinner 521 in a mixture.
The conformal machine sprays a nice coating and then the coating starts
to
recede.  Sometimes this happens even when we paint the acrylic manually.
Has anyone else ran into this problem, and what to do to overcome it?

This is a good one for the end of the day.  I'll be waiting.

Thanks again


                        P.  Lance Mayes

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------
                        Mfg. Trainer

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2