I would bet some residual copper/contaminated are encapsulated under the
mask at this site - the mask can also be thin or have poor wetting the
conductor side walls causing voids in the mask.  Properly processed PCB
surfaces with adequate soldermask application will yield a good
insulation ~ 2500 V/mil.   



Jeffrey Bush
Director, Quality Assurance and Technical Support

                          76 Technology Drive - POB 1890
                             Brattleboro, Vermont 05302-1890
                                Tel. 802.257.4571.21 Fax. 802.257.0011
                                    [log in to unmask]
                              http://www.vtcircuits.com	



-----Original Message-----
From: Scott Lefebvre [mailto:[log in to unmask]] 
Sent: Tuesday, June 08, 2004 2:32 PM
To: [log in to unmask]
Subject: [TN] Soldermask Dielectric DC properties


We have a PCB that two traces have shorted and blown a set of traces on
the PCBs.  The trace width and spacing is correct for 150 V and is not a
new design.  We recently changed PCB shops.  We found some residual
moisture about 1/8" square in close proximity of two traces after
assembly and after test.  The traces were entirely covered with LPI
soldermask.  

I understand that the moisture should be removed prior to test.  My
question is shouldn't the soldermask have insulated the two traces from
the moisture?

Scott

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2