For those of you using liquid nitrogen as a source for inert gas during
manufacturing
I have a copy of an interesting report from Lucent Technology that says
So2 levels ranging from 30 ppb to 80 ppb are not uncommon
in this "inert" gas. These levels are due to the methods generally used
to create liquid Nitrogen.

If anyone would like a copy I will forward them a copy in MicroSoft Word
format.

David A. Douthit
Manager
LoCan LLC

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2