hi,
i noticed that no one replied the last time. all i can say is that when i was at ncr we used 30 u-inch of gold over nickel for our card edge connector fingers. eventually, one of our operations decided that 3 u-inch was enough; that one made me nervous. as far as i know, 30 u-inch never gave a problem. i realize you have a somewhat different application, but the justification of 30 u-inch was that it was sufficient to be porosity free.
phil
-----Original Message-----
From: David Harman [mailto:[log in to unmask]]
Sent: Wednesday, May 12, 2004 12:33 PM
To: [log in to unmask]
Subject: [TN] AU on pads
Hello again group and I want to thank you for helping me with past
questions. I have another question regarding the thickness of gold that
should be applied to PCBA pads. We have standard gold over
nickel/copper pads. The pads are not used for any insertion but used as
a contact point for board interconnection via a zebra strip.
What is a recommended gold thickness over nickel to prevent nickel
oxidation caused by migrating nickel?
Thank you for your help again.
Thanks
David Harman
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|