Hi,

I have a design that has 270VDC between 2 adjacent layers in a 16 layer
IPC-4101/40 (polyimid) PWB. This is a high rel application and we are
designing the board for 500VDC to allow for some margin. IPC-2221
section 6.3 specifies that layer to layer spacings (dielectric
thicknesses) are to be per table 6-1 (Electrical Cunductor Spacing).
This is a change from IPC-D-275 section 3.5.3 which does not state that
table 3-1 is applicable for layer to layer spacings.

 1- Does anyone know if there is a good basis for this change between
IPC-D-275 and IPC-2221?

I have read through the archives regarding this subject and the figure
of 50V/mil (.001 inch) is quoted several times for layer to layer
spacings, which is much less than the dielectric strength shown in
IPC-2221 Table 4-1 and in IPC-4101/40. In several of the postings this
10X derating of the dielectric strength is based on experiences with
failures in single sheet prepregs and/or laminates. Some postings
surmise this is a result of voids in the material. I would assume that
the possibility of a void appearing in exactly the same locations in 2
sheets of dielectric vs.1 sheet would be greatly reduced.

2 - Does anyone have experience with layer to layer voltage gradients of
greater than 50V/mil (or 500VDC max across .003-.005" dielectric) using
2 thin layers of prepreg or laminate constructed from 2 sheets of
dielectric rather than single sheets only? If so please mention what
your material is in your response.

This adjacent layer situation occurs several times in the stackup of
this board. Due to thickness constraints the layer to layer spacing of
this board needs to be around .004"-.005" so 2 106 sheets or 1 106 + 1
1080 sheet would be what we are looking at for dielectric between the
high voltage layers.

Some past postings for reference:
http://listserv.ipc.org/scripts/wa.exe?A2=ind96&L=technet&P=R39153&I=-3
http://listserv.ipc.org/scripts/wa.exe?A2=ind96&L=technet&P=R39061&I=-3
http://listserv.ipc.org/scripts/wa.exe?A2=ind9808&L=technet&P=R48036&I=-3

Thanks for the help,
Glenn

 =============================================================================


                           Utilitek Systems Inc.

  since 1986 providing:    Mentor Graphics PCB design services,
                           Mentor consulting services,
                           Custom AMPLE development &
                           Mentor productivity Software
                               including GeomGen,
                               automatic geometry generation

                           148 Vestal Parkway East
                           Vestal, NY 13850

                   voice:  607-786-9064 x25
                   fax:    607-786-5563

                   email:  [log in to unmask]
                   web:    http://www.utilitek.com

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2