Charles,

Just imagine how uncomfortable it would be to work in a facility that vented all of its (now higer temperature) reflow ovens into the general plant air!  

Imagine the increased air conditioning load!!   .... well, that assumes that the plant is air conditioned ....

Sounds like a big energy saver to me (not)!

Yummie, and to breath all that flux!  Would not make my day!


Is this from a heating and air conditioning supplier??? ... or just a moron?

Steve Creswick - Gentex Corporation



-----Original Message-----
From: Chuck Dolci [mailto:[log in to unmask]]
Sent: Thursday, April 22, 2004 7:01 PM
To: [log in to unmask]
Subject: [LF] Reality check


Question:  Is the following statement about lead-free solder not requiring venting, etc.
  true?

"Tin-silver-copper alloys have been developed as substitutes.  The costs of these
replacement solders are only marginally higher than the lead solders but there could be
savings at the manufacturing end because the new solders will not require the venting
and management for worker and environmental protection which was formerly necessary with
lead solder during production"

Thanks

--
Charles F. Dolci
Director - Business Continuity and EH&S Programs
Sun Microsystems, Inc.

-------------------------------------------------------------------------------Leadfee Mail List provided as a service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Leadfree
To temporarily stop delivery of Leadree for vacation breaks send: SET Leadfree NOMAIL
Search previous postings at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-------------------------------------------------------------------------------

-------------------------------------------------------------------------------Leadfee Mail List provided as a service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Leadfree
To temporarily stop delivery of Leadree for vacation breaks send: SET Leadfree NOMAIL
Search previous postings at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-------------------------------------------------------------------------------

ATOM RSS1 RSS2