Based on the studies I did with the Massachusetts Lead Free Consortium
where we ran a large lead free design of experiment.  We definitely saw
visually enhancements to the quality of the lead free solder joints when
Nitrogen was utilized at 100 ppm.

In this study Nitrogen contributed as much as 10% to the visual yields on
our lead free study.

Karen Walters
Customer Quality Engineer
SKYWORKS Solutions, Inc.
20 Sylvan Road
Woburn, MA 01801
t. 781.376.3599
f. 781.376.3320
c.781.844.2227




                      "Morse, Carrie"
                      <CMorse@CIRTRONIC        To:       [log in to unmask]
                      S.COM>                   cc:
                      Sent by: TechNet         Subject:  Re: [TN] Use Nitrogen or Not!
                      <[log in to unmask]>


                      02/27/2004 01:31
                      PM
                      Please respond to
                      "TechNet E-Mail
                      Forum."; Please
                      respond to
                      "Morse, Carrie"






Yes -- If you are upgrading equipment for Pb Free, definitely have the
option for Nitrogen added to the equipment.  IF you choose NOT to use the
nitrogen, you can do so through the recipe.  It will be easier NOT to use
Nitrogen when you are plumbed for it than to Try to use Nitrogen when you
are NOT plumbed for it.

-Carrie

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Scott Lefebvre
Sent: Friday, February 27, 2004 1:26 PM
To: [log in to unmask]
Subject: [TN] Use Nitrogen or Not!


I am looking at upgrading our Reflow and Wave Solder equipment for Pb free.
I wanted to know what the consensus is for the requirement of Nitrogen for
these two systems. It seems to depend on who you ask some say you will need
Nitrogen and others say no.

Thanks,

Scott Lefebvre

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2