TECHNET Archives

March 2004

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Doug Corbett <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Fri, 19 Mar 2004 16:14:41 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (79 lines)
Go to:  http://www.stevezeva.homestead.com/

Look at "plugged via" and  "plugged via bubble"

-Doug Corbett-

-----Original Message-----
From: Nishath Yasmeen [mailto:[log in to unmask]]
Sent: Friday, March 19, 2004 1:42 PM
To: 'TechNet E-Mail Forum.'; [log in to unmask]
Subject: RE: [TN] Plugged Via bubble
Importance: Low


Hi Doug, Can you send me Steve's web page and the link so I can look at
these pics.
Thanks!
Yasmeen

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Doug Corbett
Sent: Thursday, March 18, 2004 4:18 PM
To: [log in to unmask]
Subject: [TN] Plugged Via bubble

Technetters,

Do any of you have reliability data or other experience with plugged
vias
that are subsequently plated over?

Steve has been kind enough to agree to post pictures of the "defect" on
his
website.

The micro section photos of the voids in the plug-and-cap vias. These
were
taken at 10X magnification. The voids/bubbles average .005" in diameter,
almost round. Looking at the photos you can determine approximately how
large they are by noting that the drill hole diameter is .010 inches
drilled
with a 10-mil drill size.

What potential long-term reliability concerns are there, and is this
considered acceptable for Class 2 product.


Douglas Corbett
L-3 Communications / Communication Systems - West
Senior Manufacturing Engineer - Printed Circuit Boards
(801) 594-3153

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2