The only time I've encountered this in the (far) past was when the epoxy was
not fully cured and had substantial air pocket voids.
At the time, it was being used for finepitch BGAs (like .8mm pitch or less).
There is other media's to use to fill those vias.
Non-conductive epoxy is one. It doesn't have the metal particles that can
create havoc when filling high aspect
ratio holes. I've seen this stuff used on even bigger holes than what has
been discussed here with success through assembly
cycles. (Not lead-free temperatures-yet)

Cheers,

David Hoover  aka, Groovy

http://home.earthlink.net/~dhoovy
----- Original Message -----
From: "Rick Thompson" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Tuesday, March 23, 2004 9:36 AM
Subject: [TN] PWB delamination and silver epoxy fill


We have some boards we're building for a customer that they have spec'd in a
conductive silver epoxy fill for the through-vias. During reflow, these
boards are delaminating in some areas, always radiating out from a via. The
PWB vendor is saying that they believe this is related to using the silver
epoxy with FR4 and are recommending a change to Gtek or something similar in
Tg.

My question is, is this a common occurrence with FR4 and this type of silver
epoxy fill?

Thanks in advance,


Rick Thompson
Sr. SMT Process Engineer

SMTEK International, Inc.
+1 (805) 532-2800
[log in to unmask]




_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

This e-mail and any files transmitted with it are confidential and
intended solely for the use of the individual or entity to whom
they are addressed.
If you have received this e-mail in error please notify the
originator of the message. This footer also confirms that this
e-mail message has been scanned for the presence of computer viruses.

Any views expressed in this message are those of the individual
sender, except where the sender specifies and with authority,
states them to be the views of SMTEK International Inc.

Scanning of this message and addition of this footer is performed
by SurfControl E-mail Filter software in conjunction with
CA e-trust anti-virus detection software.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2