There are several conditions you could apply:
1) 85C, 85%RH
2) 65C, 95%RH
3) 130C, 85%RH, 2 atm HAST
But, be careful when applying these test conditions. The failure mechanism
must be the same as would be expected in a user environment. There are some
published data on acceleration factors, but failure mechanism must be
considered there as well.
Glenn
-----Original Message-----
From: Andrew Medina [mailto:[log in to unmask]]
Sent: Wednesday, March 24, 2004 5:39 AM
To: [log in to unmask]
Subject: [TN] ACCELERATED AGING TEST
Importance: High
Hello Guys,
Does anybody know if there is an aging test that requires humidity,
If I set it at above the normal room condition can this speed up the
test? How can we know the relation/computation of the equivalent
year?I only have info regarding the temperature.
Andrew J. Medina
Quality Control Section
QM Department
Daeduck Phils., Inc.
Tel# : 046-437-0747 loc 293
Fax# : 046-437-0749
Mobile# : +639275312569
E-mail : [log in to unmask]
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|