Paul,
For point number one, wouldn't you qualify it much the same way you would a big BGA with a PCB base layer?
For point two, see a paper by David Hillman et al from this year's APEX.
Bev Christian
Research in Motion
-----Original Message-----
From: Paul Brown [mailto:[log in to unmask]]
Sent: March 8, 2004 7:36 AM
To: [log in to unmask]
Subject: [TN] Questions concerning piggy-back PCBs and SMD sardine
mounting
All,
I am looking for prescribed procedures and guidelines for the following modifications to an existing PCBA :
* Mounting a piggy-back PCB (probably about 25mm x 25mm) over the space left by two DIL ICs being replaced.
* Sardine mounting two SMD capacitors rather than piggy-back mounting (if you can't guess, sardine mounting is with the smallest faces on the PCB surface, largest faces together (legend out in both cases).
I do not see either of these techqniques mentioned in the tables of content that I have downloaded for IPC-7711 and IPC-7721.
I am particularly interested in the re-qualification requirements that would be necessary, such as shock, vibration, acoustic, thermal cycling.
Regards,
Paul.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|