TECHNET Archives

February 2004

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Guy Ramsey <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Tue, 10 Feb 2004 07:57:50 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (44 lines)
They should be the same, as Blair said. Sounds like the soldering iron
and mat are not connected to the same "ground". This is not an ESD
issue, rather an EOS issue and yes it could be very damaging. When the
electrical system ground is open I have measured potentials between 40
and 90 volts. That is where I would look first. What is the resistance
to ground through the iron? Do you have a GFI on the solder iron? Check
for a faulty ground at the outlet. Then check the AC box. How old is the
building?

> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Karnwal, Pankaj
> Sent: Tuesday, February 10, 2004 4:26 AM
> To: [log in to unmask]
> Subject: [TN] iron tip potential
>
>
> Dear all, hello
>
> My question about the potential deference between the
> soldering iron tip and the ESD grounded mat. I observed that
> it is about 20 to 30 volts, is it safe for ESD sensitive
> device? and is it mandatory to keep the iron tip on same
> potential with ESD grounded mat.
>
>
>
> Pankaj Karnwal
> Jr. Engineer QA
>
> Barco Electronics System  (P) Ltd.
>
WWW.barco.com
mailto:[log in to unmask]

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2