TECHNET Archives

February 2004

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Dehoyos, Ramon" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Thu, 5 Feb 2004 06:16:38 -0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (86 lines)
        Peter:
        This has been the humidity threshold people go by wherever I have
worked at.. I do not know where the 30% came from. If it came from studies
or just years of experience.
        Regards,
        Ramon

> -----Original Message-----
> From: David Douthit [SMTP:[log in to unmask]]
> Sent: Wednesday, February 04, 2004 7:06 PM
> To:   [log in to unmask]
> Subject:      Re: [TN] Facility Humidity control
>
> Peter,
>
> The general rule of thumb is to maintain rH between 30% and 50%.
>
> Below 30% there are ESD issues. Above 50% there are
> contamination/corrosion issues.
>
> David A. Douthit
> Manager
> LoCan LLC
>
> Peter L. wrote:
>
> >Technet,
> >
> >What is the typical humidity/ temperture (nominal and +/-) for a CEM
> >production environment?
> >
> >Is there an industry "acceptable" range?
> >
> >We are located here in the west coast and have seen relative humidity
level
> >varied from low 30s% (winter) to high 60s in the summer. Under what
> >conditions should a HVAC control system be introduced and without that,
> >what would be the potential impact on the overall manufacturing process?
> >
> >
> >Rgds,
> >Peter
> >
> >---------------------------------------------------
> >Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> >To unsubscribe, send a message to [log in to unmask] with following text in
> >the BODY (NOT the subject field): SIGNOFF Technet
> >To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
> >To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
> >Search the archives of previous posts at:
http://listserv.ipc.org/archives
> >Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information,
or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> >-----------------------------------------------------
> >
> >
> >
> >
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
> -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------