Terminals that will eventually have a wire(s) attached should mechanically attached to the PWB.  If the intended use of the terminal is as a test point, then I would argue the
swaging is overkill and would not do so unless the customer demanded so.

Regards,
Gary Camac

"Dehoyos, Ramon" wrote:

>         Hi Jean-François Bissonnette:
>         According to section 6.2 of the IPC J Std-001C there is a need for
> the turret terminals to be flared from 35 to 120 deg. I found out that going
> more than 40 degrees tends to crack the terminals. Specially if they are
> coated with tin instead of eutectic solder. So we made a tool that is only
> 18 degrees from vertical which by adding the opposite side it adds to 36
> degrees just over the minimum. We pressed them slightly with the tool so
> they barely rotate and still have a mechanical connection.
> Very few terminals crack using this very pointed tool.
>         Regards,
>         Ramon
>
>                                         |              |
>                                         |              |
>                                         |          |
>                                         |          |
>                                         \          /
>                                         ' \      /
>                                         ,  \       /
>                                         ,    \    /
>                                         , 18 \/
>
> > -----Original Message-----
> > From: Bissonnette, Jean-Francois [SMTP:[log in to unmask]]
> > Sent: Monday, February 16, 2004 4:32 PM
> > To:   [log in to unmask]
> > Subject:      [TN] Test points:  Question on swaging of turrets
> >
> > One simple question:  Can a turret be soldered on a PCB without being
> swaged
> > and is it acceptable?
> >
> >
> > Jean-François Bissonnette
> > Vérificateur, Contrôle de la Qualité
> > Électronique
> > Produits et Procédés
> > Vapor Rail Inc.
> >
> >
> > ***** CONFIDENTIALITY NOTE *****
> > The content contained in this e-mail transmission is legally privileged
> and confidential information intended only for the use of the individual or
> entity named herein. If the reader of this transmission is not the intended
> recipient, you are hereby notified that any dissemination, distribution, or
> copying of this transmission is strictly prohibited.
> >
> > ---------------------------------------------------
> > Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> > To unsubscribe, send a message to [log in to unmask] with following text in
> > the BODY (NOT the subject field): SIGNOFF Technet
> > To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> > To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> > Search the archives of previous posts at: http://listserv.ipc.org/archives
> > Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> > -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2