Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Tue, 10 Feb 2004 18:18:11 +0000 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Dick
Why would you need to take precautions with water based getting into
production environment?
--
Regards Graham Naisbitt
[log in to unmask]
Cell: 079 6858 2121
Office: +44 (0)1252 813706
Concoat Limited - Engineering Reliability in Electronics
NEW - HumiSeal 1H2O Bov Aerosol - NEW
Web: www.concoat.co.uk and www.concoatsystems.com
> barry, the question one has to ask is what type of conformal coating are you
> intending on using ?( which will define the type & amount of solvents
> incorporated in the formulation). once you know this, the next question to be
> addressed is what are the local regulations in regard to discharging this
> material?
> with all this in mind, than one can design and fabricate an appropriate booth/
> ventilation system with all parameters taken into consideration. if you use a
> water borne system, one should take precautions to limit the amount of
> material
> vaporized into the production environment, etc. if you would like to discuss
> this subject in more detail, please feel free to call me @ 508 870 7272
>
> regards; dick litavis ( paradign inc)
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
> additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|