The Panasonic (Panasert) MPAV2 will place connectors this size. You should
be able to source a second user machine for less than $100K. I am based in
the UK so I can't recommend any second user sources close to you.
Mark Austin
(Process Engineer)
ACW Technology Ltd
UK
===== Original Message from [log in to unmask] (TechNet E-Mail Forum.) at
19/02/04 21:19
>We have a customer with several assemblies that use large Samtec SMT
>connectors that we currently have to hand place due to equipment
>capability. I'm looking for recommendations of equipment that can handle
>and place these connectors, either automated in-line or via some sort of
>manual operator assisted alignment. The connectors are up to 150mm long,
>with some as tall as 0.900". Since cost is always an issue, I'm looking for
>solutions that would minimize the capital costs involved.
>
>Thanks in advance for any recommendations.
>
>
>Rick Thompson
>
>Sr. SMT Process Engineer
>SMTEK International, Inc.
>+1 (805) 532-2800
>[log in to unmask]
>
>
>
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
>for additional information, or contact Keach Sasamori at [log in to unmask] or
>847-509-9700 ext.5315
>-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|