TECHNET Archives

January 2004

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Miswald, Ron" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Tue, 13 Jan 2004 10:07:16 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (174 lines)
To expand on this topic, is there a minimum spacing from a chip to board
edge?  How about large chips, 2512?


-----Original Message-----
From: Bruce D Stilmack [mailto:[log in to unmask]]
Sent: Wednesday, January 07, 2004 10:54 AM
To: [log in to unmask]
Subject: Re: [TN] CC Mechanical stress


George I was about to mention the same thing.  We had this same problem on
some boards.  The CCA's were 5 to a panel and when you broke them out, the
caps on the edges of the boards (the edges that were shared) would usually
crack.  After change to parallel, we had zero cracks.

Bruce Stilmack
GDLS-TO Manufacturing Engineer
(850) 574-4773
[log in to unmask]


 

                    "Wenger, George

                    M."                     To:     [log in to unmask]

                    <George.Wenger@A        cc:

                    NDREW.COM>              Subject:     Re: [TN] CC
Mechanical stress           
                    Sent by: TechNet

                    <[log in to unmask]

                    >

 

 

                    01/06/2004 11:56

                    AM

                    Please respond

                    to "TechNet

                    E-Mail Forum.";

                    Please respond

                    to "Wenger,

                    George M."

 

 





Werner,
I agree.  I forgot to mention the solder fillet reduction.  I also forgot
to indicate that our other internal requirment is to mount ceramic chip
capacitors with their long axis parallel rather than perpendicular to the
nearest edge.

Regards,
George

George M. Wenger (908)-546-4531
Reliability Engineer
RF Power Amplifier Group
Andrew Corporation,  40 Technology Drive, Warren, NJ 07059
[log in to unmask]



-----Original Message-----
From: Werner Engelmaier [mailto:[log in to unmask]]
Sent: Tuesday, January 06, 2004 11:38 AM
To: [log in to unmask]
Subject: Re: [TN] CC Mechanical stress


Hi,
George gave good advice. A further measure is to REDUCE the size of the
solder fillets--large solder fillets act like vise-grips during
high-strain-rate
loading such as riveting and depanelizing. Large solder fillets serve no
real
purpose for samall CC's.

Regards,
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL  32174  USA
Phone: 386-437-8747, Fax: 386-437-8737
E-mail: [log in to unmask], Website: www.engelmaier.com

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

----------------------------------------------------------------------------
--------------------

This message is for the designated recipient only and may
contain privileged, proprietary, or otherwise private information.
If you have received it in error, please notify the sender
immediately and delete the original.  Any unauthorized use of
this email is prohibited.
----------------------------------------------------------------------------
--------------------

[mf2]

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2