Hi all,
There are many postings regarding components compliance to the LF requirements. I find some threatening problems in the PCB: first - PBB and PBDE should not be used as fire retardant aditives - I assume it's pretty easy, yet have to be verified. Second, the external coating - this is easy too - just specify the alternate coating according to your preferences (after all - like taste and smell it is also a question of preference - I don't like gold because of the Ni intolerability to press-fit). 

But there is another factor, that endengers the electrical performance: the exposure to extensive temperatures requires higher z-axis stability (especially in thicker PCB, because of the need of controlled impedances - 2.7 to 3.3 mm is typical here, and going to 6 mm for backplanes). This requires change of the laminates into another, which might have different electrical factors (Dk and dissipation factor, for example). This change may, in turn, require the change of the PCB routing and may be the stack-up, to ensure the geometries required for the controlled impedances. This means that we should call our designers and ask them to re-design and re-validate the products.

Any comments?

Regards
Ofer Cohen
Manager
Quality Assurance, Reliability and Production Technologies
SEABRIDGE Ltd. - A Siemens Company

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2