Bogert,
I would not say this is a new problem. It has been around since plastic encapsulated modules originated.
At the very least, pop-corning will rip wires up, mechanical overstress on the leads can disrupt bonds, contaminated mold compound could eat the bond pads off the IC..... I am sure there are a bunch more.
On the positive side, most of these issues have been addressed and virtually put to bed. Humidity control during storage helps minimize pop-corning, control over reflow parameters and mechanical stress during lead-form, etc. all help minimize problems. The mold compound is supposed to be clean and free of halides, etc.
However, I still would rather have a hermetic chip and wire device within a pacemaker!! :-)
Someone trying to "put the fear into you"?
Go hermetic!!
Steven Creswick - Gentex Corporation
-----Original Message-----
From: Bogert [mailto:[log in to unmask]]
Sent: Wednesday, January 21, 2004 5:41 AM
To: [log in to unmask]
Subject: [TN] Integrated Circuit Internal Bond Wire Failures - Seeking
Information Concerning
January 21, 2004
Folks, although this question may not be appropriate for this forum, does anyone out there have any information or technical data regarding internal bond-wire failures in non-hermetic integrated circuits (IC). It is my understanding that this is a recently uncovered problem where the internal bonds in IC''s are failing open due to presence of molecular moisture in the IC, or by outside contamination sources (e.g.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
copper).
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|