Pankaj

I've used direct plate, but not this particular chemistry.  In general, direct plate is capable of providing high reliability plated thru holes.  There are differences in performance between plated thru holes based on electroless copper and direct plate.  As with any new process, it is important that the board fabricator validate and qualify the new process.  Process control is generally not as complicated for direct plate, but it is still critical to achieve a quality plated hole.

Don Vischulis

-----Original Message-----
From: "Karnwal, Pankaj" <[log in to unmask]>
Sent: Jan 18, 2004 9:55 PM
To: [log in to unmask]
Subject: [TN] Celeco CP Direct plating process

        Dear Techneters
        We have received a communication from our local PCB supplier about
change in Electro-Less Copper plating process to a new process "Celeco CP
Direct plating process from Atotech"

      Can anybody tell me that what is the difference between and, is it the
new process  better, any  risk factor
to adopt this technology. Any experience ???

Pankaj Karnwal
Jr. Engineer QA

Barco Electronics System  (P) Ltd.
Plot no. A - 4 & 5, Sector- 5
G.B Nagar, Noida  - 201301
India
Fax.+91-120-2421691
mailto:[log in to unmask]


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2