For small FC builds we used to dry @105-110degC for at least 2 hours.
I've been told that you need to pull at least 27 inches of mercury to
attain the required vacuum. The Universal Consortium mentioned this
technique in some detail maybe 4 years ago in one of their
presentations. I think that Dan Blass was the author/presenter.
Rich Kraszewski
Advanced Manufacturing Engineer - KEDS
Phone: 812.634.4281
Pager: 812.481.3492
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Gabriela Bogdan
Sent: Friday, January 16, 2004 1:20 AM
To: [log in to unmask]
Subject: Re: [TN] MSD Question
Does anybody in this forum dry the components in a vacuum oven? Are
there any time and vacuum suggestions? What about old printed circuits
or assemblies when preparing to replace BGAs? Gaby
----- Original Message -----
From: "Dave Hillman" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, January 15, 2004 5:53 PM
Subject: Re: [TN] MSD Question
> Hi Don! Here's a quick answer - if the Sn/Pb component finish is not
> sufficiently thick you will run the risk of degrading the
> solderability - the higher the bake temperature the quicker/greater
> the degradation. Good Luck.
>
> Dave Hillman
> Rockwell Collins
> [log in to unmask]
>
>
>
>
> Donald Vischulis
> <dvischulis@earth To:
[log in to unmask]
> link.net> cc:
> Sent by: TechNet Subject: [TN] MSD
Question
> <[log in to unmask]>
>
>
> 01/14/2004 08:26
> PM
> Please respond to
> Donald Vischulis
>
>
>
>
>
>
> Just a quick question: What is your opinion of a MSD control
> procedure
the
> requires baking tin/lead terminated (coated) components every 7 days?
>
> Don Vischulis
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
> unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt
> or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at
[log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
> unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt
> or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-509-9700 ext.5315
> -----------------------------------------------------
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|