TECHNET Archives

January 2004

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Mike Fenner <[log in to unmask]>
Reply To:
Date:
Thu, 15 Jan 2004 12:28:54 -0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (138 lines)
Just to elaborate on this and other answers.
There are two types of ceramic component, nickel barrier and plain.
As Dave said the original components (plain) originated in the hybrid
thick film industry and were attached with Ag epoxy.
If these are soldered then the Pd/Ag will be leached off. This can be
slowed by the use of Sn62 instead of Sn63.
Solder processable, or SMT parts have a nickel barrier over the Pd/Ag
this prevents the leaching, the nickel itself is protected by Sn (/Pb)
coating. These can therefore be soldered with any alloy.

Solder joints made to Pd/Ag, also Sn62 joints under certain
circumstances, have a mat/frosted or even rough appearance. This
tendency can be reduced by (singly or in combination): reducing time
over liquidus, peak over liquidus, increasing ramp down rate after peak.

Regards

Mike Fenner

Indium Corporation
T: + 44 1908 580 400
M: + 44 7810 526 317
F: + 44 1908 580 411
E: [log in to unmask]
W: www.indium.com
Pb-free: www.Pb-Free.com



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Dave Hillman
Sent: Wednesday, January 14, 2004 11:05 PM
To: [log in to unmask]
Subject: Re: [TN] Silver Palladium Termination


Hi Jim! I would be very suspect of any Ag/Pd terminations. The Ag/Pd
metallization does not "age" gracefully over time as both temperature
and humidity cause either sulfidation or oxidation issues. Additionally,
Ag/Pd terminations tend to diffuse very quickly into molten solder such
that depending on your solder process time/temperatures, you can be left
with a mechanical solder-to-component body joint which is not the
metallurgical joint you intended to create.  Chapter 3.3.1 of the AWS
Soldering Handbook (ISBN 0-87171-618-6) has some good information. It is
my understanding that the Ag/Pd termination was originally developed for
use with conductive adhesives thus avoiding any diffusion/dissolution
issues. Apparently someone thought soldering to it was a good idea but
never checked with a materials engineer. Unfortunately the Ag/Pd
metallizations are making a "re-appearance" due to the Pbfree
activities. Good Luck.

Dave Hillman
Rockwell Collins
[log in to unmask]




                      "West, Jim"
                      <[log in to unmask]        To:       [log in to unmask]
                      M>                       cc:
                      Sent by: TechNet         Subject:  [TN] Silver
Palladium Termination
                      <[log in to unmask]>


                      01/14/2004 03:12
                      PM
                      Please respond to
                      "TechNet E-Mail
                      Forum."; Please
                      respond to "West,
                      Jim"






Hi,

Is there a different process required to solder to a silver palladium
termination?  We have ran these through our normal process and noticed
that the parts with they type of termination do not look very good.
Within the same reel, we have noticed some of parts look like they have
some type of oxide build up because they have a dark gray appearance,
while the others have the silver appearance.  Is this normal for this
type of termination? Should we treat these different within our process?

Thanks,
Jim

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::

This email, its content and any files transmitted with it are intended solely for the addressee(s) and may be legally privileged and/or confidential. If you are not the intended recipient please delete and contact the sender by return and delete the material from any computer. Any review, retransmission, dissemination or other use of, or taking of any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited.

Messages sent via this medium may be subject to delays, non-delivery and unauthorized alteration. This email has been prepared using information believed by the author to be reliable and accurate, but Indium Corporation makes no warranty as to accuracy or completeness. In particular, Indium Corporation does not accept responsibility for changes made to this email after it was sent. Any opinions or recommendations expressed herein are solely those of the author. They may be subject to change without notice.

:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2