Let's not get too complacent: there  are many more potential problems
than have been cited. One of the **essential** tests which will show up
many chemical and physical problems is the "pressure cooker" test or,
more scientifically, the "autoclave" test. Put a coated assembly in a
domestic pressure cooker with a litre of water, well above the water
level, and boil it vigourously for 48 hours (not letting it boil dry, of
course). If a microscopic examination reveals any vesication,
blistering, lifting of the coating or milkiness, you know you are in
DEEP trouble. This will reveal a whole host of problems, including some
prior contamination of the boards and/or components, hygroscopicity of
the flux residues, poor curing of the coating for whatever reason,
reaction between the flux chemistry and the coating chemistry etc.

Brian

Macko, Joe @ IEC wrote:

> Fellow Techeads,
>
> It has been suggested by one of our CMs that it is acceptable to conformal
> coat (type AR) over no clean flux residue.  Would anyone like to share their
> opinions or experience on this subject.  Conformal coating over residue does
> not sound like the correct thing to do.  thanks
>
> joe
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> -----------------------------------------------------
>
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2