Hello Technet:
One of our standard designs is to mount an RF PWB into a housing with
screws.  The screws have a dual function, one being to hold the PWB in
place, the other is to ground the PWB to the housing.  An ongoing problem is
that, over time, the PWB material flows, causing the screws to loosen
slightly, thus compromising the ground.  On approach is to mount grounding
terminals to the side wall of the housing and connect a wire from it to the
PWB.  I was wondering if there is any other techniques or products available
that may solve this problem.

Thanks for your assistance,

Jim Marsico
Senior Engineer
Production Engineering
EDO Electronics Systems Group
[log in to unmask] <mailto:[log in to unmask]>
631-595-5879

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2