I don't need a Christmas miracle . . .the 0.4% I mentioned was 0.4% per
degree C temperature change. For my expected 50 degree C change from
ambient and self heating, I will get a 20% change in resistance.
I can probably cope with an additional 20% ambiguity caused by board
geometry and thickness variations. I have found a raw board specification
of 10% on the starting copper thickness.
Today's questions:
1. What variations can I expect to see (on finished boards) with a
standard production specification of 2-oz. Cu ?
2. Are any of "you guys" willing to share success (or failure) stories
of your attempts at "board etch Cu for current sense resistors"?
Thanks,
Carl
-----Original Message-----
From: Edward Szpruch [mailto:[log in to unmask]]
Hi,
As far as I remember IPC allow 10% variations in copper thickness.Take into
account that 2 oz is unit based on weight while you are describing
thickness.Add to this topography of the foil from lamination side, thickness
reduction as result of different surface preparation processes - it seems
you need X-mass miracle to get to 4% while you are expecting 0.4%. Good luck
and Happy New Year Edward
> -----Original Message-----
>
> I have a project that seems to be a good candidate for a current sense
> resistor made as a part of the PCB. I am using the free calculator,
> PCBTEMP, from the UltraCAD website (http://www.ultracad.com/calc.htm)
> for geometry calculations. I need to know the expected variability in
> thickness, batch to batch, for the copper foil on 2-oz stock. I can
> live with the 0.4%
> TC of the Cu, but I need to evaluate all the other variables in my error
> budget before I present my proposal. I would appreciate any success (or
> horror) stories from people who have (not) used the board copper as a
> current sense method.
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|