Yes, you can get a class 2 PCB and then also receive class 3 workmanship on the assembly but you can't expect it without a contractual agreement.  Other industries that may use class 3 are medical, veterinary, and any other device that must have high reliability or that may cause a health/safety risk if the device fails.

Kat

YCOINT.COM 12/30/03 08:51AM >>>
I am looking for your opinions and experience.
IPC has the 3 levels of classification for the Acceptability pf Electronic
Assemblies, and IPC also offers 3 levels of classification for the
fabrication of Printed Circuit boards.

My question is this- Can I purchase a Class 2 Fabricated Printed Circuit
Card, and Expect to get Class 3 Workmanship Solder Joints from Manufacturing
Wave Soldering and Employee Hand Soldering?


One additional question, Other than the Military and NASA, what kinds of
products do you feel require the guidelines of a Class 3 Board and or
Assembly.


Any input is greatly appreciated.

Marie A. Dobbs
Training and Development Specialist
100 Technology Drive
Westminster, MA 01473
Phone:  1-978-731-6827
Fax:  1-978-731-6950

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2