Hello Yordan,

There are few more things to consider...

I've seen that some of the replays U got, already have pin-pointed some of 
the issues... There is actually nothing wrong with 65,45:34,54 ratio 
First.... As Edward and Dale already said, it seems that the analyses is 
not done with a professional approach and U are not aware of the 
contamination level in the bath...
Secondly, there is a phenomenon in the solder bath that needs to be 
considered when taking a sample...
The density of Pb and Sn are significantly different... And if I assume 
that U have a large soldering pot and the frequency of use is low, U can 
get phenomena where Pb and Sn separate partially meaning that the 
composition on the top of the pot involves more Sn then on the bottom of 
the bath where U get larger amount of Pb molecules...
Alloy needs to be disturbed to restore SnPb ratio evenly in the bath...
That's why U should let soldering wave pump around the solder for some 
time before soldering and before taking a solder sample....
I assume that the sample is taken from the surface from the soldering bath 
and that could explain the higher level of Sn in the result U got from 
analysis...

If my assumptions are right, I would suggest that U repeat the sample 
analysis and disturb the bath before taking a sample...
Then, send it to someone that would make a serious analysis....
And if the ratio still bothers U, U can simply restore it by adding pure 
Lead or pure Tin... No advanced calculations needed here...
Ratio between Pb and Sn are generally not a problem that gives U 
headache... 
The contamination level is a bigger issue and this is more complicated to 
fix and often involves production disturbance...
 
Regards,
Sasha


*************************************************************************
Sasha Miladinovic - Production Engineering 
Amersham Biosciences, PCB Production, Umeå
Tel:      +46 (0) 90 150 232
Fax:     +46 (0) 90 138 372
E-mail: [log in to unmask]
*************************************************************************





Yordan Venev <[log in to unmask]>
Sent by: TechNet <[log in to unmask]>
2003-12-03 13:58
Please respond to "TechNet E-Mail Forum."; Please respond to Yordan Venev

 
        To:     [log in to unmask]
        cc: 
        Subject:        [TN] SnPb Solder pot composition.


We have made a composition analysis of our solder wave solder pot and
discovered a deviation of the SnPB content. The Sn percentage had gone up 
to
65.45% and the Pb content down to 34.54%. I suppose there will be a 
(small)
change in the constitutional behaviour of the alloy - some bigger range of
the liquid-to-solid stage. Except this, what should we be aware of in
practice in regards to solder joint quality and reliability? We continue 
to
maintain the pot temperature at 250 deg C (482 deg F).

Any inputs will be appreciated!

Best regards,
Yordan Venev

********************************************************
CENTILLION LTD.
7-th km Tzarigradsko shosse Blvd.
ATM Center
1784 Sofia, BULGARIA
Tel. :(+359 2) 974 47 51, 965 84 95, 965 58 85
Fax :(+359 2) 974 47 52
mail to: [log in to unmask]
www.centillion-bg.com



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] 
or 847-509-9700 ext.5315
-----------------------------------------------------



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2