Reuven,

I assume that conventional coatings did not do the job? Maybe this was an
application issue?

There is no question that Paralene is the ultimate coating - but as with all
other coatings, it is not without its own drawbacks:

It is a batch process
It is more expensive overall, than most conventional coatings
It requires a clean surface
It is not easily repaired, and conventional coatings are normally used to
carry out the repair
Masking has to be 100% perfect - don't forget through hole via's adjacent to
connectors, trimmers etc.

Hope this helps
--
Regards Graham Naisbitt

[log in to unmask]

Cell: 079 6858 2121
Office: +44 (0)1252 813706

Concoat Limited - Engineering Reliability in Electronics

NEW - HumiSeal 1H2O Bov Aerosol - NEW

Web: www.concoat.co.uk  and  www.concoatsystems.com



> Hi Perylene users,
>
> Can you share with your experience and inform the + and - of this process?
>
> I have last week visited one of the users site and it seems promising.
>
> I have long experience with spraying systems and not vacuum systems.
>
> Best  Regards
>
> Reuven
>
>
>
>
>                     Graham Naisbitt
>                     <Graham.Naisbitt@CON         To:      [log in to unmask]
>                     COAT.CO.UK>                  cc:
>                     Sent by: TechNet             Subject: Re: [TN] Foreign
> material on top of the conformal coating
>                     <[log in to unmask]>
>
>
>                     12/12/2003 18:02
>                     Please respond to
>                     "TechNet E-Mail
>                     Forum."; Please
>                     respond to Graham
>                     Naisbitt
>
>
>
>
>
> Bruce
>
> If you are applying epoxies and other materials after conformal coating,
> just be sure that the solvents (if any) are not affecting the coating
> during
> their application and curing.
>
> Otherwise this should simply be regarded as a cosmetic issue.
>
> Cleaning after all these processes is unlikely to be a good option, as the
> coating will now be expected to withstand your cleaning process...and
> surface cleaning using brushes, swabs etc., are only likely to be moving
> the
> stuff around on the surface rather than removing it.
>
> Hope this helps
> --
> Regards Graham Naisbitt
>
> [log in to unmask]
>
> Cell: 079 6858 2121
> Office: +44 (0)1252 813706
>
> Concoat Limited - Engineering Reliability in Electronics
>
> NEW - HumiSeal 1H2O Bov Aerosol - NEW
>
> Web: www.concoat.co.uk  and  www.concoatsystems.com
>
>
>> Hey guys,
>>    I have be hit recently on a couple of occasions by the quality folks
>> over "foreign material" that is present on CCA's after conformal coating.
>> On quite a few boards we install heat sinks after CC and usually use an
>> epoxy to aid in heat transfer as well as loctite on the mounting screws.
> I
>> have been gigged for the residuals (just smears really) whether it is on
>> the solder pads or not.  I know that we all are concerned with material
>> left over directly on the solder connections, but I am having trouble
> with
>> this one from a logical standpoint.  I mean lets face it, you definitely
>> can't test for the presence of ionic contaminants or anything, but I know
>> the general impression is the boards should be clean.
>>
>> I know the simple answer here is to clean up all the residuals (and
>> everyone is instructed to do that), but there are times when stuff just
>> happens.
>>
>> Your thoughts
>>
>> Bruce Stilmack
>> GDLS-TO Manufacturing Engineer
>> (850) 574-4773
>> [log in to unmask]
>>
>> ---------------------------------------------------
>> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>> To unsubscribe, send a message to [log in to unmask] with following text in
>> the BODY (NOT the subject field): SIGNOFF Technet
>> To temporarily halt or (re-start) delivery of Technet send e-mail to
>> [log in to unmask]: SET Technet NOMAIL or (MAIL)
>> To receive ONE mailing per day of all the posts: send e-mail to
>> [log in to unmask]: SET Technet Digest
>> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
>> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
>> additional information, or contact Keach Sasamori at [log in to unmask] or
>> 847-509-9700 ext.5315
>> -----------------------------------------------------
>>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
> additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2