Ken,
IPC-A-610C Page 12-75 calls out:
Acceptable Class 1,2,3- Less than 10% voiding in the Ball to Board
Interface.
Process Indicator Class 2,3- 10-25% voiding in the Ball to Board Interface.
-voiding in the BGA solder ball to board interconnection up to 25%may or may
not be a reliability issue and should be determined in your process
development.
-BGA solder joint reliability studies performed at some industry locations
show that limited voiding in BGA balls does not impact long term
reliability.
Defect Class 1,2,3- More than 25% voiding in the Ball to board interface.
Barry
-----Original Message-----
From: Ken Patel [ mailto:[log in to unmask] <mailto:[log in to unmask]> ]
Sent: Tuesday, December 16, 2003 10:09 AM
To: [log in to unmask]
Subject: [TN] Rejection criteria for voids in BGA solder joints
All,
What are the current rejection criteria for voids in BGA solder joints? I am
preparing assembly notes in this regards.
Any help will be highly appreciated.
Re,
Ken Patel
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
<http://listserv.ipc.org/archives>
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
<http://www.ipc.org/contentpage.asp?Pageid=4.3.16> for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|