I agree. Of course this does not mean you can soak them in the rain and run
) I think it is there so that there is a rating so you are not guessing what
requirements if any on ic's vs there was nothing on package/datasheet (ie:
supplier/vendor forgot to label/looking in the wrong place)

>
>                                  James Cagle
> Tyco Printed Circuit Group-Hayward Division
>               email: [log in to unmask]
>


-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Macko, Joe @ IEC
Sent: Thursday, December 11, 2003 1:50 PM
To: [log in to unmask]
Subject: [TN] J-STD-033A, moisture level 1 ?


Fellow Techs,

The holidays are almost upon us.  Happy Holidays to all.

I have been asked if parts rated by the supplier at a moisture
classification level 1 have to be packaged in a moisture barrier bag with
desiccant and a humidity indicator card since they have a moisture level
rating.  Since a moisture classification level 1 has an unlimited floor life
at factory ambient conditions, I would think not.

Look forward to some commentary on this question.  thanks

joe

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2