That maybe so Sherif but in a mass production environment I suspect you
have to take special care to achieve such a good tolerance - after all
the top surface of the board will vary with it's thickness.

I'd suggest +/-0.10mm, or +/-0.004" to those of you who object to
'communist' dimensions, would be a reasonable assumption in the absence
of better data.


Regards,


[log in to unmask] wrote:
>
> Kathy,
>
> Some N.C. drilling machines manufacturers claim that their machines can do
> controlled depth drilling with +/-0.001" accuracy. I know that Hitachi is
> one of them. I assume for controlled depth drilling the depth of the hole,
> hence the tolerance, is measured from the top side of the board. For
> dimensional and tolerance purpose, counterbore could be considered as
> controlled depth drilling. If the right NC drilling machine is used,
> theoretically, you should be able to get +/- 0.001" tolerance.
>
> Sherif Refaat, Eng.
>
>  -----Original Message-----
>  From: Kathy Bergman [SMTP:[log in to unmask]]
>  Sent: Monday, November 03, 2003 3:46 PM
>  To:   [log in to unmask]
>  Subject:      [TN] Counterbore depth tolerance
>
>  Hello Netters,
>
>  Any ideas of what a standard depth tolerance of a typical counterbore on a
>  PCB might be?
>
>  Thanks
>  K Bergman
>
>  ---------------------------------------------------
> > > Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> > > To unsubscribe, send a message to [log in to unmask] with following text
> in
> > > the BODY (NOT the subject field): SIGNOFF Technet
> > > To temporarily halt or (re-start) delivery of Technet send e-mail to
> > > [log in to unmask]: SET Technet NOMAIL or (MAIL)
> > > To receive ONE mailing per day of all the posts: send e-mail to
> > > [log in to unmask]: SET Technet Digest
> > > Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> > > Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> > > for additional information, or contact Keach Sasamori at [log in to unmask]
> or
> > > 847-509-9700 ext.5315
> > > -----------------------------------------------------
> >
> > ---------------------------------------------------
> > Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> > To unsubscribe, send a message to [log in to unmask] with following text in
> > the BODY (NOT the subject field): SIGNOFF Technet
> > To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> > To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> > Search the archives of previous posts at: http://listserv.ipc.org/archives
> > Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> > -----------------------------------------------------
> >
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> -----------------------------------------------------

--
Eric Christison
Mechanical Engineer
STMicroelectronics
33 Pinkhill
Edinburgh
EH12 7BF

tel:    +44 (0)131 336 6165
fax:    +44 (0)131 336 6001

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2