Hi Brian,
At Bell Labs we used recangular pads besides round ones to increase density,
not for inspection. A side benefit was a slight increase in reliability. For a
reference look at:
Engelmaier, W., "BGA and CGA Solder Attachments: Results of Low-Acceleration
Test and Analysis," Proc. Surface Mount International Conf., San Jose, CA,
August 1995, pp. 344-358; also in Proc. NEPCON West ‘96, Anaheim, CA, February
1996, pp. 1020-1036.
Regards,
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Fax: 386-437-8737, Cell: 386-316-5904
E-mail: [log in to unmask], Website: www.engelmaier.com
---------------------------------------------------