TECHNET Archives

October 2003

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Franklin D Asbell <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Wed, 29 Oct 2003 07:47:53 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (30 lines)
TechNet will not allow sending attachments...but I believe I know what you
are observing...

A thin layer of mask covering metal within the clearance area...yes?

This may be caused by a few process variables.

1- Tack cure too long, making developing difficult - make sure you are tack
curing correctly
2- Poor vacuum during exposure - light/energy may be reflecting under the
areas where it should not, slightly exposing/curing that mask - check that
your vacuum is correct, also, if you are using mylar, check that it is not
dented, damaged, loose, etc.
3- Poor developing, pressure, temperature, chemistry, time in solution, all
may affect this.

My first guess would be developing...

Franklin

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2